A water district’s office network and treatment controls may share vendors, connections, or staff, but they cannot be managed as though they were the same environment. A change that is routine on an office laptop could interrupt a process an operator depends on.

Cybersecurity for water and wastewater utilities starts with understanding those dependencies. Identify what is connected, who can reach it, and what must keep working. Then separate the work your business IT provider can perform from the operational technology work that requires plant-specific expertise.

This guide is for district managers, operations supervisors, finance leads, and board members who need a practical starting point without assuming they have a dedicated security team.

What to take from this guide

  • Review business IT and operational technology separately, including the connections between them.
  • Investigate remote access and internet exposure with the people responsible for safe operation. Do not make unplanned changes to control systems.
  • Use EPA’s assessment and assistance resources to inform priorities, and name who will act on the results.

Why the water sector needs a different approach

Office systems support billing, payroll, purchasing, records, and communication. Operational technology, or OT, monitors or controls physical processes. It can include programmable logic controllers (PLCs), human-machine interfaces (HMIs), supervisory control and data acquisition (SCADA) systems, and telemetry at remote sites.

Safety and service continuity deserve explicit attention in an OT environment. So do the accuracy of process information and the protection of sensitive records. It is not a choice between keeping the plant running and protecting data; the review needs to account for both.

NIST’s Guide to Operational Technology Security addresses the performance, reliability, and safety considerations that distinguish OT from conventional IT. Those differences affect what can be installed, changed, or tested and when that work can occur.

The sector’s exposure is documented. In February 2026, EPA reported identifying cybersecurity vulnerabilities at 277 water systems during 2025. That is a count of systems where EPA identified vulnerabilities, not a count of 277 confirmed breaches or a measure of every utility’s risk.

Build an inventory with operations, IT, and your integrator

Begin with existing diagrams, equipment records, vendor contracts, and conversations with the people who use the systems. Avoid treating an automated network scan as the default first step in a control environment; discovery methods need technical review for the equipment involved.

Organize the inventory into five areas:

Area

Questions to resolve

Business IT

Which systems support billing, finance, email, records, and office work? Who maintains them?

Computers and devices

Which workstations, servers, laptops, and remote-site computers are in use? Which run business applications, control functions, or both?

Remote access

How do staff and outside providers connect? What can each connection reach?

Operational systems

Which PLCs, HMIs, SCADA components, and telemetry links support treatment and collection? Who understands their dependencies?

Vendor access

Which integrators and equipment suppliers retain access, under whose approval, and for what purpose?

 

Include the date and source of the information. An old diagram may be a useful starting point, but it should not be treated as proof that every current connection is documented.

For example, an integrator’s remote support connection may still be needed after a project closes. The question is whether someone has reviewed its purpose, access limits, and owner—not whether every long-standing connection should immediately be removed.

Keep the business IT and OT scopes distinct

For office systems, the work may include software support, account security, endpoint monitoring, backups, and recovery testing. For OT, it may involve carefully designed network separation, controlled remote access, specialized monitoring, and changes coordinated around operational constraints.

A Windows-based HMI is still part of a control environment. Do not assume that an agent suitable for an office PC can be installed there safely. The operator, integrator, equipment vendor, and responsible technical staff should validate compatibility, testing, rollback, and change approval before deployment.

MoreAware Sentry is a monitoring-only service, not an OT security engagement. Any business IT coverage must be defined in the Service Order. Do not infer that it covers treatment controls or includes patching, containment, incident response, or recovery. Those needs require separate scoping and appropriate expertise.

When evaluating a provider, ask for the actual devices, data sources, and responsibilities in scope. The monitoring versus managed IT services guide can help with the service distinction, but it does not replace an OT-specific technical review.

Give remote access a focused review

EPA and CISA have warned about internet-exposed HMIs, including the possibility of unauthorized users viewing or changing settings. Their guidance calls for identifying exposure, limiting access, using stronger authentication, and working with system integrators.

Ask your technical team to establish which paths reach business systems and which reach operational systems. Identify shared credentials, former staff access, vendor accounts without a current owner, and connections that bypass the intended access process.

Where supported and safely implemented, use individual accounts, multifactor authentication, and access limited to the work being performed. For a legacy control system that cannot support those controls directly, have the qualified team evaluate an appropriate access gateway or other compensating measures. Record the remaining limitations.

Agree how vendor access is approved, enabled, reviewed, and withdrawn. Time-limited access can be appropriate, but a utility must also account for essential support and operating needs. Do not remove a connection until its function and a safe alternative are understood.

If a control interface is publicly exposed, escalate that finding promptly to the operations lead and qualified technical support. Reducing the exposure is important; improvising a network change without understanding its effect on treatment is not an acceptable substitute for a coordinated response.

Strengthen the business systems your staff use every day

Review office computers for current security coverage and supported software. Confirm who reviews alerts, who handles updates, and how findings move into approved work. Include devices that leave the office and administrative computers located at the plant, while checking whether any also serve a control function.

For email and cloud accounts, check authentication methods, administrative privileges, and unusual account activity. The Microsoft MFA requirements guide explains the distinction between Microsoft’s management-access mandate and the broader work needed to establish account coverage. It also covers the separate passkey transition.

Back up the records needed to operate and recover: billing, engineering documents, configurations where appropriate, and essential administrative data. Arrange recovery tests with the responsible staff and vendors. A successful backup job alone does not demonstrate that the necessary service can be restored. NIST’s small-organization quick-start guide includes backup testing, inventory, access management, and monitoring among its recommended practices.

The Public-Sector Security Visibility Checklist can organize the business IT discussion. It is not an OT assessment and does not determine whether the treatment environment is secure.

Document the dependencies that matter during an interruption

Ask operations to identify which systems must function for treatment and collection to continue safely. Record what happens if telemetry, remote access, a critical workstation, or an outside provider is unavailable.

Manual operation belongs in that discussion only where the utility has a safe, validated procedure and trained staff. Record its limits, staffing needs, and the circumstances in which it can be used. Do not assume an automatic process can simply be switched to manual.

Also identify knowledge dependencies. Who understands the SCADA configuration? Who can obtain vendor support? Where are current recovery instructions stored? A person leaving the organization can expose the same documentation gap as an incident.

Keep an appropriately secured, accessible copy of essential contacts and procedures that does not depend entirely on the affected network. Do not place passwords or sensitive system details in a general marketing worksheet or public board packet.

Prepare for an incident before choosing the recovery order

Bring operations and IT into the recovery discussion together. Leadership can identify service priorities; technical staff and vendors must establish the dependencies and checks needed to restore those services safely.

Record the incident coordinator, backup coordinator, integrator, insurer, relevant state contacts, and qualified incident response support. Review reporting obligations with the people responsible for them rather than borrowing another district’s deadline.

EPA’s cybersecurity planning resources include an incident action checklist and response plan materials. Its exercise resources can help a utility test contacts, decisions, and dependencies in a discussion-based exercise. During an actual suspected incident, use the established response process and qualified responders rather than waiting for a routine assessment appointment.

Use the available EPA resources

EPA maintains a water-sector cybersecurity resource hub. The resources serve different purposes, so choose the one that matches the question you need answered.

Resource

How it can help

Water Sector Cybersecurity Evaluation Program

EPA describes free cybersecurity assessments for drinking water and wastewater systems, with a risk-mitigation planning template.

Cybersecurity Technical Assistance Program

A request route for help with cybersecurity practices, questions, and planning. Confirm the assistance available for your situation.

Planning resources

Water-sector actions, response planning, and supporting tools to organize work.

Exercises and technical assistance courses

Materials and training to practice coordination and identify gaps before an incident.

Cybersecurity response resources

Incident reporting and response references; not a promise that a particular responder is retained by your utility.

 

An assessment can help establish priorities. It does not perform every corrective action or replace ongoing maintenance. Assign owners to the findings and determine which changes require operator involvement, vendor approval, funding, or a planned outage.

Eight questions for the next management review

  1.    Do we have a current picture of business IT, OT, and their connections?
  2.    Which systems are essential to safe operation, and what do they depend on?
  3.    Can any control interface be reached from the public internet?
  4.    Who approves and reviews staff and vendor remote access?
  5.    Which business devices and accounts are monitored, and who acts on findings?
  6.    When did we last test an appropriate recovery procedure?
  7.    Who coordinates an incident when the usual lead is unavailable?
  8.    Which assessment findings or support deadlines need a funded action plan?

Bring the answers into the district’s own budget process. Do not use a city budget calendar without confirming it applies. Include the labor, testing, documentation, and ongoing support required for proposed changes, with finance determining the accounting treatment.

Decide where outside help fits

A practical next step is to compare the identified work with the available skills and capacity. Business IT monitoring may address a visibility gap. Managed support may be needed to perform ongoing work. A control-system finding requires an OT-qualified review rather than an assumption that a general IT subscription covers it.

To discuss business IT visibility, contact MPTG and request a review. Bring the known systems, current providers, and unresolved questions. That review should establish the appropriate scope before any work involving the operational environment is considered.

Frequently asked questions

1.     Where should a small utility start?

Assemble the system and remote-access picture with operations, IT, and the integrator. Use EPA’s assessment resources to help prioritize findings. Escalate known exposure or a suspected incident promptly rather than waiting for the inventory to be perfect.

2.     Can endpoint monitoring secure the treatment plant?

Not by itself. Office endpoint coverage does not establish coverage of PLCs, HMIs, SCADA, or their connections. The operational environment needs its own assessment and approved controls. Sentry should not be described as an OT security service.

3.     Should we turn off every vendor connection?

First determine what each connection supports. Remove unnecessary access through an approved change process, and control access that remains necessary. Operations and qualified technical staff should confirm the effects before making changes.

4.     Is EPA’s cybersecurity evaluation free?

EPA describes its Water Sector Cybersecurity Evaluation Program as providing free assessments to drinking water and wastewater systems. Confirm the program’s current arrangements directly. Assessment findings can still require paid implementation, equipment, or specialist support.

Related Articles

When Security Monitoring Is No Longer Enough: 7 Signs to Review

When Security Monitoring Is No Longer Enough: 7 Signs to Review

Your monitoring reports are arriving, but some findings remain unresolved. Or a question about an account requires information from several systems that you cannot bring together. Those are reasons to review how security work is handled, not automatically reasons to...

What Does Endpoint Monitoring Actually Tell You?

What Does Endpoint Monitoring Actually Tell You?

Endpoint monitoring can tell you which covered devices are reporting, whether selected security tools are operating, and what activity may need review. The details depend on the product, its configuration, and the service you have purchased. For a business owner,...